永久不封国产毛片AV网煮站_黑人又大又粗又硬XXXXX_永久免费AV网站_日韩人妻高清精品专区

?

解決方案

THE SOLUTION

首頁 -  解決方案 -  變風量與低溫送風空調

解決方案

THE SOLUTION

變風量與低溫送風空調

變風量系統簡介VAV SYSTEM BRIEF

變(bian)(bian)(bian)(bian)(bian)風(feng)(feng)量(liang)空調系統(tong)是全空氣系統(tong)的(de)一種形(xing)式,其工(gong)作(zuo)原理(li)是在各房間設(she)置(zhi)變(bian)(bian)(bian)(bian)(bian)風(feng)(feng)量(liang)裝(zhuang)置(zhi),當空調房間負(fu)荷變(bian)(bian)(bian)(bian)(bian)化(hua)時(shi)變(bian)(bian)(bian)(bian)(bian)風(feng)(feng)量(liang)裝(zhuang)置(zhi)改(gai)變(bian)(bian)(bian)(bian)(bian)送(song)入房間的(de)風(feng)(feng)量(liang)來滿(man)足室內負(fu)荷變(bian)(bian)(bian)(bian)(bian)化(hua),保證(zheng)房間溫度穩定(ding)在設(she)定(ding)值(zhi);同時(shi),系統(tong)根據各個(ge)變(bian)(bian)(bian)(bian)(bian)風(feng)(feng)量(liang)裝(zhuang)置(zhi)的(de)風(feng)(feng)量(liang)變(bian)(bian)(bian)(bian)(bian)化(hua),變(bian)(bian)(bian)(bian)(bian)頻(pin)調節(jie)(jie)空調機組送(song)風(feng)(feng)機頻(pin)率,改(gai)變(bian)(bian)(bian)(bian)(bian)系統(tong)的(de)總送(song)風(feng)(feng)量(liang),滿(man)足系統(tong)空調負(fu)荷變(bian)(bian)(bian)(bian)(bian)化(hua)的(de)需求(qiu),達到節(jie)(jie)能的(de)目(mu)的(de)。

7.jpg

系統特點

與其它空(kong)調(diao)系統相比(bi),節能和舒適是其主(zhu)要特(te)點,具體(ti)如下:

節能顯著

▲風機裝機容量減少:與定風量空(kong)調(diao)系(xi)統(tong)相比,變風量系(xi)統(tong)計(ji)算總負(fu)荷(he)時可以適當考慮各房間(jian)負(fu)荷(he)發生的同時性,一般(ban)可減少(shao)風機(ji)裝機(ji)容量約10~20%。

▲風機運行能耗降低:空調系(xi)統在全年大部分(fen)時(shi)間部分(fen)負荷運(yun)行(xing),而變風量空調系(xi)統隨著負荷的變化(hua)改變空調送(song)風量,因此可大大降低送(song)風機的能耗(hao)。假設空調系(xi)統全年平(ping)均負荷率為60%,利(li)用變頻技術則可節(jie)約(yue)風機運(yun)行(xing)能耗(hao)約(yue)75%。

▲過渡季新風作冷源:減少過渡(du)季節的(de)制冷主機能耗(hao)。


空調品質高

▲避免室內溫度過冷或過熱:變(bian)風量裝置根據需要(yao)進行空(kong)調(diao)(diao)房間溫度獨立控制,與定風量空(kong)調(diao)(diao)系統相(xiang)比(bi)可以有效防止室內溫度過冷或過熱,提高空(kong)調(diao)(diao)舒適性。

▲杜絕冷凝水污染:與風機盤管系(xi)統(tong)相(xiang)比,新風與回風經過混合、過濾、冷(leng)卻/加熱和(he)除濕等集中(zhong)處理后送入(ru)空調房(fang)間,避免了冷(leng)凍水(shui)和(he)冷(leng)凝(ning)水(shui)進入(ru)房(fang)間而造成的細菌滋(zi)生和(he)吊頂污染(ran)問題,空調衛生水(shui)平提高。

▲實現全新風運行:全(quan)(quan)空氣系統在過渡(du)季節或空調季節夜(ye)間進行全(quan)(quan)新(xin)風(feng)送風(feng),營(ying)造“會呼吸的建筑”,空氣品質(zhi)提高。

▲運行安靜,室內噪聲低:風機盤管(guan)系統存在較大的(de)室內(nei)噪(zao)(zao)音(yin),而(er)變風量系統的(de)噪(zao)(zao)音(yin)主要集(ji)中在機房,用戶端噪(zao)(zao)聲較低(di),從而(er)保(bao)證室內(nei)安靜運行。


智能化水平高

送風系(xi)統及室內空(kong)氣品質(zhi)各參數(shu)精確(que)控制和顯示,樓(lou)宇智能化(hua)水平(ping)高。

 

 

1.jpg

變風量空調系統示意圖

 


源牌變風量技術RUNPAQ VAV TECHNOLOGY

低溫送風技術

變風(feng)(feng)(feng)量空(kong)調系統的送(song)(song)風(feng)(feng)(feng)溫度根據實際情況(kuang)可以采用(yong)常(chang)溫送(song)(song)風(feng)(feng)(feng)或(huo)低(di)溫送(song)(song)風(feng)(feng)(feng)。所謂(wei)常(chang)溫送(song)(song)風(feng)(feng)(feng),空(kong)調送(song)(song)風(feng)(feng)(feng)溫度一(yi)(yi)般在(zai)13~16℃之間(jian);所謂(wei)低(di)溫送(song)(song)風(feng)(feng)(feng),空(kong)調一(yi)(yi)次送(song)(song)風(feng)(feng)(feng)溫度在(zai)7~10℃之間(jian)。

低(di)溫(wen)送風系(xi)統,亦稱CAD系(xi)統(Cold  Air Distribution System),由于顯(xian)著降(jiang)低(di)了送風溫(wen)度,具有以(yi)下優點:

▲降低系統投資:在相同供冷量的情況下,低溫送(song)風(feng)系統比常溫送(song)風(feng)系統減少送(song)風(feng)量30~40%,相應空調(diao)機組和風(feng)管尺(chi)寸均可(ke)減少,從(cong)而(er)降低系統投資;

▲降低運行費用:降低空調(diao)送風的風機運行能(neng)耗約20~30%;

▲提高空調舒適度:系統(tong)除(chu)濕能力強,提高空(kong)氣品(pin)質;送風量減(jian)少,有效(xiao)降低空(kong)調噪聲。

低(di)溫(wen)送風(feng)系(xi)統7~10℃的送風(feng)溫(wen)度(du)通常借助1~5℃的低(di)溫(wen)冷(leng)源(yuan)而獲得(de),在有低(di)溫(wen)冷(leng)源(yuan)(如冰(bing)蓄冷(leng)系(xi)統)可(ke)(ke)利用時(shi),源(yuan)牌變風(feng)量(liang)空調可(ke)(ke)以有效結合(he)變風(feng)量(liang)和低(di)溫(wen)送風(feng)這兩項技術(shu)的優點(dian),并(bing)提供精(jing)確、可(ke)(ke)靠的系(xi)統控制,使(shi)得(de)整個系(xi)統更具節能和舒適優勢。


變風量系統應用

變風(feng)量空(kong)(kong)(kong)調(diao)系統的(de)(de)本質特征是調(diao)節各個(ge)分(fen)區(qu)的(de)(de)送風(feng)量實現(xian)對各個(ge)分(fen)區(qu)負(fu)荷的(de)(de)調(diao)節,因(yin)此可以廣泛(fan)用于辦公、寫字樓等(deng)負(fu)荷有變化的(de)(de)舒適性空(kong)(kong)(kong)調(diao)場所,同時也可應用于空(kong)(kong)(kong)調(diao)送風(feng)量無恒定要求的(de)(de)有負(fu)荷變化的(de)(de)工藝空(kong)(kong)(kong)調(diao)場所。

源牌各(ge)種不(bu)同類型的(de)變風量末端都有各(ge)自不(bu)同的(de)適用場合,在實際應用過程(cheng)中根據具體(ti)空調負荷情況(kuang)以(yi)及系統整體(ti)使用情況(kuang)做出判斷,具體(ti)見(jian)表(biao)1。

2.jpg

表(biao)(biao)1 源牌(pai)變風量(liang)空調系(xi)統(tong)應用表(biao)(biao)


控制策略

變(bian)風(feng)量(liang)空調控(kong)制(zhi)(zhi)主要(yao)包(bao)括房間(jian)溫度(du)(du)控(kong)制(zhi)(zhi)、送(song)風(feng)溫度(du)(du)控(kong)制(zhi)(zhi)、送(song)風(feng)機(ji)(ji)(ji)變(bian)頻控(kong)制(zhi)(zhi)、回風(feng)機(ji)(ji)(ji)變(bian)頻控(kong)制(zhi)(zhi)、新(xin)風(feng)控(kong)制(zhi)(zhi)、開機(ji)(ji)(ji)關機(ji)(ji)(ji)控(kong)制(zhi)(zhi)、低溫送(song)風(feng)系(xi)統防(fang)結露(lu)控(kong)制(zhi)(zhi)以及提供多種面向運行管理(li)和用戶需求的功能等。

3.jpg

房間溫度控制

由VAV BOX 實現對房間溫度控(kong)制(zhi),一般根據控(kong)制(zhi)方式有(you)壓(ya)力有(you)關和壓(ya)力無關控(kong)制(zhi)兩(liang)種。

▲壓力有關型:VAV控(kong)制器根據室內(nei)(nei)溫度實測(ce)值與設(she)定值的偏差來進(jin)行風量調整;屬(shu)單(dan)級控(kong)制,控(kong)制簡單(dan),但送風量易受到(dao)風管內(nei)(nei)壓力變化的影響,房間溫度波動較(jiao)大(da)。

▲壓力無關型:VAV控制器先根據室內溫度(du)實測值(zhi)與設定值(zhi)的(de)偏差計算(suan)風(feng)(feng)量(liang)(liang)設定值(zhi),利用風(feng)(feng)量(liang)(liang)傳感器測量(liang)(liang)實際風(feng)(feng)量(liang)(liang)值(zhi),再根據風(feng)(feng)量(liang)(liang)設定值(zhi)和實際風(feng)(feng)量(liang)(liang)值(zhi)的(de)偏差進行風(feng)(feng)量(liang)(liang)調(diao)整;屬(shu)串級控制,控制較復雜;送風(feng)(feng)量(liang)(liang)不易受(shou)到風(feng)(feng)管內壓力變化(hua)的(de)影響,房間溫度(du)波動小。


送風溫度控制

根據送(song)風(feng)溫度調(diao)節(jie)冷凍水/熱水電動調(diao)節(jie)閥,使送(song)風(feng)溫度穩(wen)定(ding)在設定(ding)值。


送風機變頻控制

送風(feng)機變(bian)(bian)頻控(kong)制(zhi)是變(bian)(bian)風(feng)量(liang)控(kong)制(zhi)的(de)(de)關(guan)鍵技術,其控(kong)制(zhi)決定變(bian)(bian)風(feng)量(liang)系統(tong)能耗(hao)的(de)(de)降低程度(du),同(tong)時也對(dui)系統(tong)運行的(de)(de)穩定性起著重要的(de)(de)作用。目前(qian)一般有(you)定靜壓(ya)控(kong)制(zhi)、可(ke)變(bian)(bian)靜壓(ya)控(kong)制(zhi)、變(bian)(bian)靜壓(ya)控(kong)制(zhi)和總風(feng)量(liang)控(kong)制(zhi)等方法。

▲定靜壓控制:在送風管上設置靜壓傳感器,當末端風量變化時,變頻調節送風機的頻率(lv)使靜壓實測(ce)值趨于設定值。

▲可變靜壓控制:在(zai)定靜壓控制的(de)基礎上,判斷各個變風(feng)量末端的(de)閥位情況,根(gen)據系統的(de)需求進行靜壓值的(de)自動(dong)設定,使系統靜壓在(zai)滿足各變風(feng)量末端需求的(de)情況下維持在(zai)較低的(de)水平,更大限(xian)度地(di)節約變風(feng)量空調系統的(de)動(dong)力(li)消耗和(he)運(yun)行費(fei)用。

▲變靜壓控制:采集每個(ge)末(mo)端的(de)(de)閥位信號并進行判斷,變頻調節送風(feng)機的(de)(de)頻率盡量使VAV風(feng)閥處于較大開度(du)狀(zhuang)態,把系統靜(jing)壓降(jiang)低(di),因而能(neng)大限度(du)的(de)(de)降(jiang)低(di)風(feng)機轉(zhuan)速以達到(dao)節能(neng)目(mu)的(de)(de)。

▲總風量控制:根據計算的設(she)定風(feng)量與實(shi)際風(feng)量比較,進(jin)行(xing)風(feng)機(ji)變頻調節。

源牌變風量控(kong)制技術根據系(xi)統的形式與類別,兼顧(gu)穩定和節(jie)能,選用合適的變頻(pin)控(kong)制策略

4.jpg


新風控制

包括(kuo)系統最小新(xin)風控(kong)(kong)制和過渡季節全新(xin)風控(kong)(kong)制。


開/關機控制

根(gen)據需(xu)要各設備啟停(ting)按(an)順(shun)序程序控制。


SMART-VAV ? 自控系統

系統組成

RUNPAQ VAV自控(kong)系統(tong)由(you)硬(ying)件和軟(ruan)件組(zu)成。硬(ying)件包括系統(tong)控(kong)制器、VAV控(kong)制器、執行(xing)器(電(dian)動水閥、電(dian)動風閥和變(bian)頻(pin)器等(deng)(deng))、傳感器(溫(wen)度、濕度、壓(ya)力(li)等(deng)(deng))及上位機(ji)監控(kong)工作站;軟(ruan)件包含編程軟(ruan)件、組(zu)態(tai)運行(xing)軟(ruan)件以及源牌自主知識產權(quan)的SMART-VAV  控(kong)制軟(ruan)件。

RUNPAQ VAV自控系統具有很強(qiang)的擴展(zhan)功能,增加遠程 l/O 模(mo)塊可(ke)直接控制制冷(leng)機房設(she)備、給排水設(she)備等,可(ke)提供(gong)與樓宇智能化系統通訊接口。

5.jpg

控制功能

▲空調/采(cai)暖/過渡季(ji)工況切換(huan)及參(can)數控制(zhi)

自(zi)動切(qie)換各種(zhong)運行(xing)工況,對目標運行(xing)參(can)數進行(xing)遠程設定(ding)和控(kong)制(zhi)。

▲設備監控

對空調機組、VAV BOX、閥門等設(she)備(bei)進行(xing)集中監視(shi)與控制。

▲數據記錄和管理

對(dui)溫(wen)度、壓力(li)、頻(pin)率等數(shu)(shu)據(ju)(ju)進(jin)行記(ji)錄,提供多種(zhong)數(shu)(shu)據(ju)(ju)管理(li)功能如數(shu)(shu)據(ju)(ju)采集、歷史數(shu)(shu)據(ju)(ju)存儲查詢(xun)、打印及各種(zhong)數(shu)(shu)據(ju)(ju)報(bao)表生(sheng)成。


系統特點

▲開放式的系統6.jpg

采用Windows 通用技術(shu),SQL-server數(shu)據(ju)庫技術(shu),Ethernet網絡技術(shu);

支撐Profibus、BAC-net,Lonworks,ModBus,OPC、TCP/IP等(deng)國(guo)際標準協議;

便捷升級。

▲可靠性與節能(neng)性的完美結(jie)合

自控(kong)核心采用工業級的可編程(cheng)序控(kong)制器(qi),保證(zheng)系統可靠運行;

采用可(ke)靠(kao)的電動閥和傳感器元器件,保(bao)證(zheng)在惡劣環境下也能可(ke)靠(kao)、經

久運行;

自主開(kai)發的自控軟(ruan)件程序,滿(man)足VAV空調(diao)的穩定和節(jie)能運行,并(bing)在項目(mu)

中廣泛應用;

▲  卓越的數據采集(ji)和(he)先(xian)進的操作系統,友好的管理界面。

 


? ?